Device description, 1 scope of delivery 2.2 hardware description – KROHNE ALTOSONIC V12 EN User Manual
Page 11
![background image](/manuals/369187/11/background.png)
DEVICE DESCRIPTION
2
11
ALTOSONIC V12
www.krohne.com
04/2013 - 4002643502 - MA ALTOSONIC V12 R02 en
2.1 Scope of delivery
2.2 Hardware description
The flowmeter is designed to meet explosion safety requirements based on:
• the application of an explosion proof (Ex d) electronics enclosure according to IEC 60079-1
• using Ex certified transducers according to IEC 60079-18
• using cables with an Ex d certified connector according to IEC 60079-1 to connect to the
transducers
• installation of the cabling between the electronics and the transducers complying with
enhanced safety
enhanced safety
enhanced safety
enhanced safety requirements according to IEC 60079-7.
The flowmeter consists of a meter body with one or two (twin meter) electronic units installed on
top of it.
For smaller diameters the meter body is fully machined hence no welding is done.
For larger diameters the meter body is a welded construction.
INFORMATION!
Do a check of the packing list to make sure that you have all the elements given in the order.
INFORMATION!
The instrument is delivered in a seaworthy, reinforced wooden crate. Inspect the packing
carefully for damages or signs of rough handling. Report damage to the carrier and to the local
office of the manufacturer.
Figure 2-1: Scope of delivery
1 Product documentation
2 CE Declaration
3 Flowmeter in ordered version
4 Optional: flow conditioner, spare parts and / or installed impact indicators
INFORMATION!
Calibration reports and project specific documents are in the meter's databook that is sent
separately.