beautypg.com

Yokogawa Removable Chassis DX1000N User Manual

Page 70

background image

Common Operations

IM 04L41B01-01E

2-3

1

2

3

4

5

6

7

8

9

10

11

12

App

Index

2.3 Setting the Time Correction Operation during

Memory Sampling

This function gradually corrects the time when the time is changed while Memory
Sampling is in progress.
For a description of the time correction operation, see section 1.10.

Setup Screen

Press

MENU (to switch to setting mode), hold down FUNC for 3 s (to switch to basic

setting mode), and select the

Menu tab > Time Settings.

Setup Items

• Time settings > Time deviation limit

Time deviation limit

Current time

Specified time

When the time deviation between the time on the DX and the specified time is within

±(the value specified here), the time on the DX is gradually corrected. Otherwise,
the clock is corrected immediately. Note that time is not corrected on DXs with the
Advanced security function (/AS1 option) when the specified time is over the time
deviation limit. (Firmware version numbers 4.11 and later)

Settings

Description

10 s to 5 min

The time deviation limit.

Off

Disables the function that gradually corrects the time.

Example: If

Time deviation limit is set to 10s and the time on the DX is 10 hours 21

minutes 15 seconds, the time on the DX is gradually corrected if the specified time is
between 10 hours 21 minutes 5 seconds and 10 hours 21 minutes 25 seconds.

Note

On DXs with the Advanced security function (/AS1 option), you cannot change the time during
memory sampling if the time deviation limit is set to OFF. (Firmware version number 4.11 and
later)

This manual is related to the following products: