4.4 Display the Statuses of All Channels on One
Screen (Overview Display)
This section explains how to use the overview display.
For a description of the function, see section 1.3.
Procedure
• Showing the Display
1.
Press
DISP/ENTER to show the display selection menu.
2.
Press the
arrow keys to select OVERVIEW, and press DISP/ENTER.
The display appears.
• Changing the Displayed Contents
1.
Press
DISP/ENTER to show the display selection menu.
2.
Press the
right arrow key to display the sub menu.
3.
Press the
up and down arrow keys to select the sub menu item.
Overview display sub menu
JUMP TO TREND: Switches to the trend display of
the smallest group number that
includes the channel selected
with the cursor.
JUMP TO DIGITAL: Switches to the digital display of
the smallest group number that
includes the channel selected
with the cursor.
JUMP TO BAR:
Switches to the bar graph display
of the smallest group number that
includes the channel selected
with the cursor.
JUMP TO ALM SUM: Switches to the alarm summary
CURSOR OFF:
Clears the cursor
CURSOR ON:
Displays the cursor
(Not displayed with the default settings. To display, see section 5.17)
TAG DETAIL ON:
When a tag does not fit into the
typical tag display space, the
alarm and measured values are
covered so that the tag can be
displayed completely.
TAG DETAIL OFF: Priority is not given to tag display.
(Appears when Tag Number is set to Use. See section 5.2 for details.)
4.
Press
DISP/ENTER to change the displayed contents.
To close the menu without changing the displayed contents, press the
ESC key.
• Showing the Trend, Digital, Bar Graph Display Containing the Specified
Channel
1.
Press the
arrow keys to move the cursor, and select a channel.
Cursor (white Frame)
2.
Switch to the trend, digital, or bar graph display according to the procedure
described in “Changing the Displayed Contents.”