beautypg.com

10 other functions, 10 other functions -54, Time related functions – Yokogawa Removable Chassis DX1000N User Manual

Page 65

background image

1-54

IM 04L41B01-01E

1.10 Other Functions

Time Related Functions

• Time Correction

The DX internal clock can be changed in the following manner.

Method

Description

Key operation

Sets the DX internal clock to the specified time.

Event action function

Synchronizes the DX internal clock to the nearest hour.

SNTP client function

Sets the DX internal clock to the time retrieved from an SNTP

server.

Time Correction Operation

The time correction operation varies depending on whether the memory sampling is in

progress or not.

Status

Operation

Memory sampling stopped The DX internal clock is changed immediately.
Memory sampling

The DX internal clock is gradually corrected. While the time is

being gradually adjusted, the date/time in the status display section

is displayed in yellow.

Operation of Gradually Correcting the Internal Clock

If the time deviation between the time of the DX internal clock and the correct time (the

specified time) is within a specified value, the DX clock is adjusted gradually at 40 ms
for each second. Otherwise, the clock is corrected immediately. The maximum value
of time deviation (tm in the figure below) can be selected in the range of 10 s to 5 min.

Time specified using keys or

retrieved from an SNTP server

Range in which the time is gradually

adjusted

Nearest

hour

Time deviation

Time when the remote control

signal is applied

(Time on the DX)

tm

tm

Range in which the time is gradually

adjusted

Time on

the DX

Time deviation

tm

tm

Example: When changing the time to 12 hours 55 minutes 35 seconds when the

internal clock is 12 hours 55 minutes 32 seconds

The time deviation of 3 seconds is adjusted 40 ms per second. The
internal clock will be synchronized to the specified time 75 seconds later.

• Date Format

You can select the display format of the data from “2005/09/28,” “09/28/2005,”

“28/09/2005,” and “28.09.2005.”

For the setting procedure, see section 2.4.

• Time Zone

Set the time difference between the location where the DX is used and GMT.
For the setting procedure, see section 2.2.

• DST (Daylight Saving Time)

If you are using the DX in an area with daylight saving time, enter the daylight

saving time starting and ending dates, and the DX will automatically change the time
accordingly.

For the setting procedure, see section 2.1.