Yokogawa Removable Chassis DX1000N User Manual
Page 233
7-6
IM 04L41B01-01E
• Displaying an Event Level Switch Status List (Release number 3 or later)
Display the status of the event level switch. For the operating procedure, see section
4.5.
• Resetting the Match Time Timer (Release number 3 or later)
Operation ends when a match time timer whose timer action is set to single expires.
To use such a match time timer again, you must reset it.
1.
In operation mode, press
FUNC.
The FUNC key menu appears.
2.
Press the
Match T Reset soft key.
* This soft key appears when a match timer whose timer action is set to single has expired.
3.
Press the
soft key with the match time timer number of the timer that you want to
reset.
The match time timer that you specify is reset.
Explanation
• Resetting the Relative Timer
Restarts the timer.
• The resetting of the timer is considered to be a timeout. (If the timer is used as an
event, the action is executed.)
• If the timer is used in TLOG computation on the /M1 or /PM1 math option and
TLOG computed value reset at each interval is specified, the computed result is
reset.
• Resetting the Match Time Timer (Release number 3 or later)
This operation resets an expired match time timer so that it can operate again.
• The resetting of a match time timer does not count as a timer expiration (and it will
not count as an event action event).
• This operation can be used with match time timers whose timer action is set to
single.
• If the timer is used in TLOG computation on the /M1 or /PM1 math option and
TLOG computed value reset at each interval is specified, the computed result is
reset.
7.1 Setting the Event Action Function (Including the remote control function of the /R1 and /PM1 options and
the USER key)