App index flow of data recording and storage – Yokogawa Removable Chassis DX1000N User Manual
Page 38
1-27
IM 04L41B01-01E
Overview of Functions
1
2
3
4
5
6
7
8
9
10
11
12
App
Index
Flow of Data Recording and Storage
Measured data is recorded once to the internal memory and then saved to the external
storage medium.
Measurement
channel
Computation
channel
..
.
..
.
Data of another device
(via communication)
Display/Event
data
CF card
USB memory (/USB1 option)
External storage medium
Setup data
Display
Internal memory
FTP server on
the network
Sampling
Save the data
Screen image
data
Save
Load
Internal Memory
Display data and event data are held in files in the internal memory. The data area also
stored on the external storage medium in files.
Save the data
Directory on the external storage medium
Manual
sampled data Report data
Display data and event data
FTP server on
the network
Internal memory
File
......
......
Sampling
1.4 Data Storage Function