Yokogawa Touch Screen GP20 User Manual
Page 98

5-2
IM 04L61B01-01EN
Code
Message
Description
Corrective Action
3118
CRC illegal!
The file may be corrupt.
Check the disk condition, and recover the file.
Contact the administrator if you cannot solve the
problem.
3119
Already signed
Already signed at the current
user level.
Contact the administrator if you cannot solve the
problem.
3120
Not registered user.
User name, user ID, or
password entry is incorrect.
Check them, and try again.
Contact the administrator if you cannot solve the
problem.
3121
There is no signature no.
The user does not have
signature privileges.
Check the signature privileges.
Contact the administrator if you cannot solve the
problem.
3122
%d times password input failure.
Processing terminated.
%d is the number of failures.
Enter the correct user name, user ID, and
password. Contact the administrator if you cannot
solve the problem.
3123
%d times password input failure.
The user will be disabled.
This user’s privileges will be
disabled. %d is the number of
failures.
Enter the correct password.
Contact the administrator if you cannot solve the
problem.
3124
%s File is not found.
The setting data file could not
be found.
Place the relevant setting file in the folder
containing the data file.
3125
Cannot perform authentication.
There is a problem with the KDC
server.
Unable to connect to the
KDC server or unable to
authenticate because the
KDC server setting has been
changed. KDC authentication
is also not possible if the time
zone on the PC is changed
while Universal Viewer is
running. Authentication is
not possible if there a time
difference of 5 minutes or more
between the PC and the KDC
server.
Contact your administrator.
3132
Failed to start Hardware
Configurator.
Unable to start because
Hardware Configurator is not
available.
Install the Hardware Configurator.
3133
Insufficient sufficient memory to
display all files.
Insufficient memory on the PC.
This message appears when
you open a file or link files.
Check the available memory on your PC.
We recommend you increase the amount of
memory or use a 64-bit OS and software.
5.1 Troubleshooting