See table 5.57, Table 5.58 system commands – Watlow PPC-2000 User Manual
Page 241
PPC-2000 User’s Guide
Chapter 5: LogicPro and Modbus Reference
Doc.# 30002-00 Rev 2.3
Watlow Anafaze
213
Table 5.58
System Commands
Database
Offset
Modbus
Address
Name
Reset
After
Host
Write
Action
1
04051
Reload
Defaults
Reset
Load defaults to most run-time
parameters. The exceptions are
protocol, baud, parity, address,
system HW config, system com-
mands, system status, program
version, change data queue,
system error log, real time clock
and analog input calibration
data.
2
04052
Reserved
N/A
3
04053
Reserved
N/A
4
04054
RAM Clear
Reset
Reset
Clear RAM, reset controller and
load defaults
5
04055
Watchdog
Test
Reset
Force watchdog timeout
6
04056
Start Logic
Reset
Start logic program
7
04057
Reserved
N/A
8
04058
Stop Logic
Reset
Stop logic program
9
04059
Loop
Startup
Latched
0=Start control loops in off
mode. Undo not available.
1=Start control loops from last
mode stored in memory.
10
04060
AC
Frequency
Latched
0=60Hz
1=50Hz
11
04061
Logic Star-
tup
Latched
0=Start logic program when
commanded.
1=Start logic program on star-
tup.
12
04062
Reset PPC
Reset
Reset controller
- 12LS Controller (111 pages)
- 8LS Controller (140 pages)
- 8PID Controller (55 pages)
- Addendum to EZwarePlus (50 pages)
- ANASCAN (62 pages)
- ANASOFT (95 pages)
- ANAWIN 2 (154 pages)
- ANAWIN 3 (23 pages)
- Calibrating Watlow Series 988 Family Process Controls (19 pages)
- CAS (98 pages)
- CAS200 (124 pages)
- CLS (180 pages)
- CLS200 (251 pages)
- CLS200, MLS300 and CAS200 (92 pages)
- Control Console (12 pages)
- CPC400 (230 pages)
- DIN-A-MITE Style A (9 pages)
- DIN-A-MITE Style B (14 pages)
- DIN-A-MITE Style C (22 pages)
- DIN-A-MITE Style D (9 pages)
- DIN-Mount Adapter Instruction Sheet, Rev A (1 page)
- Dual DAC (4 pages)
- EM Gateway (28 pages)
- E-Safe Hybrid Relay Rev B (4 pages)
- E-SAFE II Hybrid Power Switch (4 pages)
- EZwarePlus Programming (264 pages)
- EZ-ZONE PM (111 pages)
- EZ-ZONE PM PID (125 pages)
- EZ-ZONE PM Express Limit (34 pages)
- EZ-ZONE PM Express (35 pages)
- EZ-ZONE PM Integrated Controller (181 pages)
- EZ-ZONE RM Limit Module Rev C (127 pages)
- EZ-ZONE RMA Modul (79 pages)
- EZ-ZONE RMC (236 pages)
- EZ-ZONE RME (124 pages)
- EZ-ZONE RMH (161 pages)
- EZ-ZONE RUI/Gateway (62 pages)
- EZ-ZONE RM-Scanner-Modul (140 pages)
- EZ-ZONE ST (97 pages)
- F4 External Event Board - Rev.B (2 pages)
- HG Series Mercury Displacement Relay (6 pages)
- LogicPro (296 pages)
- Mercury Relay or MDR Retrofit (13 pages)
- MICRODIN (24 pages)
- MICRODIN (106 pages)