PPC-2000 User’s Guide

Chapter 3: Operating with AnaWin 3

Doc.# 30002-00 Rev 2.3

Watlow Anafaze

133

Select the Dig I/O button to configure or monitor PPC Digital
I/O parameters.

I/O names are located in the first column. The I/O names
identify each I/O point. Names for Processor (PPC-2010) and
Digital I/O (PPC-204X) modules differ slightly from Digital Out
(PPC-206X) and Digital In (PPC-207X) names. Processor and
Digital I/O names include an I/O type designator because those
modules support digital, count, and frequency types. For
example, a Processor I/O name, PPC1:Proc 0.0.2 indicates PPC
#1, digital I/O on the processor module (which has module
address 0), I/O type (0=digital) and point #2. See Figure 3.21 for
a breakdown of this example. Alternatively, the Digital Out
I/O name, PPC1:DO 41.2 indicates PPC #1, Digital Out module
with address 41, and point #2. See Figure 3.22 for a breakdown
of the example. See Table 3.17 on page 134 for module type
abbreviations.

See Table 2.10 on page 39 for a list of module I/O numbers
corresponding to the TB50 terminals.

Figure 3.21 PPC-2010 and PPC-204X Digital I/O

Names

Figure 3.22 PPC-206X and PPC-207X Digital I/O

Names

PPC1:Proc 0.0.2

module address

controller number

module type

module I/O number

I/O type

PPC1: DO 41.2

module address

controller number

module type

module I/O number