Configuring 78 – Maple Systems OIT Family User Manual
Page 78
3. In the Key group box, choose the option button for the screen dependent function key
you want to configure.
4. In the Action drop down list box, choose the action you want this screen dependent
function key to perform.
5. If you selected Push On/Off, Momentary, or Latched, in the Address group box,
select the PLC coil address to use for this screen dependent function key.
NOTE:The OIT5400 does not allow you to set a unique PLC coil address for each screen
dependent function key’s global function. Instead, you must select a starting PLC coil
address for the block of 5 consecutive screen dependent function key coils.
6. If you selected Screen, Dnload Recipe, or Upload Recipe in the Screen scroll box,
select the stored screen number to display when this screen dependent function key is
pressed.
7. If you selected Screen, Dnload Recipe, or Upload Recipe and want to use the
password feature, in the Password drop down list box, select the appropriate password
level. For more information on passwords, refer to the Passwords section in this
chapter.
8. Repeat steps 3 through 7 for each screen dependent function key.
9. Choose the Done button to return to the Screen-Dependent Function Key Editor dialog
box.
10. Choose the Done button to return to the OITware-200 main screen.
Configuring a screen dependent function key for a specific stored screen:
1. In the screen editor, display the screen you want to configure the screen dependent
function key for.
2. In the screen editor, choose the button for the screen dependent function key you
want to configure. The Screen-Dependent Function Key Editor dialog box appears.
Key Types
78
1010-0099, Rev. 07