32

CATC F

IRE

I

NSPECTOR

2.01

C

HAPTER

4

User’s ManualRecording 1394 Traffic

• SBP Fetch Agent Offset: Define up to two SBP fetch agent offsets. Specify the offsets

in hexadecimal and select a register from the drop-down list. It's not necessary to enter
both high 16 bits and low 32 bits; if just one is entered, then the other is considered to be
a “don't care.”

Data Pattern Editors

The Data block pattern, PHY pattern fields, Header patterns, and Quadlet header patterns
event groups allow you to edit the contents of the packets in order to define recording
actions.

1. Click the Edit button to access the Edit...Pattern dialog.

2. Select a tab to work with. Each tab contains a bit pattern template.

3. Enter bit pattern, Mask, or Match values.

Bit patterns should be entered in binary (1 or 0); use “X” for irrelevant values. Mask
and Match values should be entered in hexadecimal. Hint: Use the X, 0, and 1 buttons
on the right to change all of the bit values to X, 0, or 1.

4. Press OK to return to the Recording Options dialog.

5. Check the box marked “Use” to enable the pattern event group in the Event Groups list.

4.1.3 Action Options

Use the Actions tab of the Recording Options dialog to set up the sequencing and filtering
of the events that you selected on the Events tab. The Actions tab allows you to set complex
dependencies and actions for the events.

Figure 4-3: Recording Options dialog: Action options