3 action options, Action options – Teledyne LeCroy FireInspector - Users Manual User Manual
Page 42

32
CATC F
IRE
I
NSPECTOR
2.01
C
HAPTER
4
User’s ManualRecording 1394 Traffic
• SBP Fetch Agent Offset: Define up to two SBP fetch agent offsets. Specify the offsets
in hexadecimal and select a register from the drop-down list. It's not necessary to enter 
both high 16 bits and low 32 bits; if just one is entered, then the other is considered to be 
a “don't care.”
Data Pattern Editors
The Data block pattern, PHY pattern fields, Header patterns, and Quadlet header patterns 
event groups allow you to edit the contents of the packets in order to define recording 
actions.
1. Click the Edit button to access the Edit...Pattern dialog.
2. Select a tab to work with. Each tab contains a bit pattern template.
3. Enter bit pattern, Mask, or Match values.
Bit patterns should be entered in binary (1 or 0); use “X” for irrelevant values. Mask 
and Match values should be entered in hexadecimal. Hint: Use the X, 0, and 1 buttons 
on the right to change all of the bit values to X, 0, or 1.
4. Press OK to return to the Recording Options dialog.
5. Check the box marked “Use” to enable the pattern event group in the Event Groups list.
4.1.3 Action Options
Use the Actions tab of the Recording Options dialog to set up the sequencing and filtering 
of the events that you selected on the Events tab. The Actions tab allows you to set complex 
dependencies and actions for the events.
Figure 4-3: Recording Options dialog: Action options