1 general recording options, General recording options – Teledyne LeCroy FireInspector - Users Manual User Manual
Page 38

28
CATC F
IRE
I
NSPECTOR
2.01
C
HAPTER
4
User’s ManualRecording 1394 Traffic
4.1.1 General Recording Options
Use the General tab of the Recording Options dialog to define generic recording settings,
such as the recording type, hardware filtering, buffer size, and trigger position.
To set general recording options:
Step 1
Open the Recording Options dialog.
The General tab is displayed by default.
Step 2
Set the Recording Type. Recording Type choices are as follows:
•
Snapshot
—
A snapshot recording works similarly to using a tape
recorder: recording begins when the Record button is pressed, and it stops
when either the Stop button is pressed or the buffer is filled.
•
Manual Trigger
—
A manual trigger recording begins when the Record
button is pressed. Recording continues until either the Trigger button on
the analyzer box is pressed or the Stop button is pressed in the application.
If the Trigger button is pressed, recording will stop automatically when
the amount of data specified by the Trigger Position has been collected.
•
Event Trigger
—
An event trigger recording begins when the Record
button is pressed. Recording continues until either the trigger conditions
are met or the Stop button is pressed in the application. If the trigger
conditions are met, recording will stop automatically when the amount of
data specified by the Trigger Position has been collected.
Step 3
(Optional) Select from the following Options:
Figure 4-1: Recording Options dialog: general options