Teledyne LeCroy PeRT3 Phoenix System User Manual
Page 81
Teledyne LeCroy PeRT
3
Phoenix System User Manual
79
Reset/ Initialize Block
Teledyne LeCroy
Initialization
The DUT Initialization panel allows the user to select an initialization command
sequence. The options displayed here are dependent on the protocol selected, but
typically include Loopback, Frame Level, Custom, None, New State Machine, Connect
Host, Connect Device, Connect, Connect with Options and No Init. Loopback will place
the DUT into a loopback mode for testing. If no standard "enter loopback test mode"
command exists in that protocol, but the device vendor supports a custom command,
that command can be entered using the Pattern Editor (see
“Creating Test Patterns” on
page 83
) and then selected from the drop‐down menu of existing patterns in the
Sequence field of this panel. This also allows the testing to change between bit level
errors and frame level errors by selecting the desired method from the Count drop‐down
menu.
Figure 8.12: Initialization Panel
Automation
The Automation panel allows the user to specify reset conditions that might be required
during automated testing. Reset on each test case will force a reset each time a new test
case begins, Auto reset on lost lock will reset the system and attempt to recover the lock
when lost and Prompt user to reset prompts the user to reset.
Figure 8.13: Automation Panel