System control ribbon -- analysis tab – Teledyne LeCroy PeRT3 Phoenix System User Manual
Page 64
62
Teledyne LeCroy
System Control Ribbon ‐‐ Analysis Tab
Other Channel
If Other Channel is selected, the test will run on the specified channel until the tests on
the other channels that are currently running terminate. Typically you would select this
option when doing "victim/aggressor" testing and you want to send a specific pattern on
the "aggressor" channels while testing the effects of cross‐talk on the "victim" channel.
At least one active channel should have a specific termination criteria. Setting all
channels to terminate on Other Channel would be the equivalent of specifying Run
Forever.
Manual Stop Only
If Manual Stop Only is selected, the test will run on the specified channel until it is
stopped manually.
Note:
The test termination conditions can be channel‐specific. If different termination conditions are
selected on different channels, the test will continue to run until all termination conditions on all
channels have been met.
Eye Preview
The Eye Preview panel provides a calculated simulation of the expected jitter eye diagram
as it would be displayed on an oscilloscope. The eye preview is useful for quickly
determining the approximate level of signal impairment based on the current system
settings (see
Figure 6.22 on page 62
).
Note the simulated Eye Preview does not include the affects of low frequency SJ because
this affect is typically cancelled out by a PLL and does not generally show up on most
scope eye diagrams. Also, including this affect in the calculated eye diagram is generally
not useful as it often results in a completely closed eye.
Figure 6.22: Eye Preview Panel
System Control Ribbon -- Analysis Tab
For discussion of the controls available under the Analysis tab, see
“Analysis and Reports”
on page 93
.