Trigger Counter

Checking the

Reset trigger counter before starting a new acquisition checkbox clears the trigger counter

es an arm acquisition command. This applies when you have set a trigger Holdoff

n either time or events:

each time the oscilloscope issu
condition in the

Trigger dialog i

The default condition of this control is off (unchecked).

Performance Optimization

You can set up the oscilloscope to optimize either calculating speed or display speed. If the display update rate is

play. If acquisition and analysis are more important, optimize for

hen persistence or averaging is used, giving higher priority to

pdate rate.

at the extremes:

of primary concern to you, optimize for Dis
analysis. Optimizing for analysis can be useful w
waveform acquisition at the expense of display u

The choices are presented as a spectrum with highest values

In the menu bar touch

Utilities; then touch Preferences in the drop-down menu.

Tou

E-mail

Before you can send e-mail from the oscilloscope, it must first be configured.

1. In the menu bar touch

Utilities, then Preference Setup... in the drop-down menu.

2. Touch

the

E-mail tab.

3. Choose an e-mail server protocol:

MAPI (Messaging Application Programming Interface) is the Microsoft

interface specification that allows different messaging and workgroup applications (including e-mail, voice
mail, and fax) to work through a single client, such as the Exchange client included with Windows 95 and
Windows NT. MAPI uses the default Windows e-mail application (usually Outlook Express).

SMTP (Simple

Mail Transfer Protocol) is a TCP/IP protocol for sending messages from one computer to another through a
network. This protocol is used on the Internet to route e-mail. In many cases no account is needed.

4. If you chose MAPI, touch inside the

Originator Address (From:) field and use the pop-up keyboard to type in

the instrument's e-mail address. Then touch inside the

Default Recipient Address (To:) field and use the

pop-up keyboard to enter the recipient's e-mail address.

5. If you chose SMTP, touch inside the

SMTP Server field and use the pop-up keyboard to enter the name of

your server. Touch inside the

Originator Address (From:) field and use the pop-up keyboard to type in the

instrument's e-mail address. Then touch inside the

Default Recipient Address (To:) field and use the pop-up

keyboard to enter the recipient's e-mail address.

nd a test e-mail text message by touching the

Send Test Mail button. The test message reads

ch one of the optimization icons.

6. You can se

"Test mail from [name of oscilloscope's email address]."