IAI America PCON-SE User Manual
Page 88

76
4. Description of Operating Functions
4.4.9
Pitch Feeding by Relative Coordinate Specification
For the target position in the position table, relative coordinate specification is also available. Therefore, it can be
used in constant-pitch positioning (constant-pitch feeding).
(1) Operation example in the position no. The following is the description of an example of positioning
with a 50 mm pitch from position No. 1. Create a position table as shown below. Operational
completion is judged by PLC’s executing count control. The combined use of the zone signal
allows a double check specification mode.
Example of position table
No.
Position
[mm]
Zone +
[mm]
Zone –
[mm]
Incremental Comment
0 *
*
* 0
1 100.00
300.50
99.50
0
2 50.00 300.50
99.50
1
*Indicates the relative coordinate specification with the teaching pendant.
Position 1
50 mm
pitch
Forward end
direction
Last work
Zone output signal
Set the coordinate value for the next last work to the positive-side boundary value.
=
- ERC2 (138 pages)
- ERC2 (188 pages)
- ERC3 (438 pages)
- ERC (153 pages)
- RCA-E (53 pages)
- RCA-P (42 pages)
- RCB-101-MW (38 pages)
- RCP2-C (178 pages)
- RCS-E (102 pages)
- RCA-A4R (72 pages)
- RCA-RA3C (114 pages)
- RCA-SRA4R (56 pages)
- RCA2-RA2AC (100 pages)
- RCA2-SA2AC (92 pages)
- RCA2-TA4C (134 pages)
- RCD-RA1D (40 pages)
- RCP2-BA6 (72 pages)
- RCP2-GRSS (130 pages)
- RCP2-HS8C (126 pages)
- RCP2-RA2C (120 pages)
- RCP2-RTBS (80 pages)
- RCP2W-SA16C (46 pages)
- RCP3-RA2AC (60 pages)
- RCP4-RA5C (82 pages)
- RCP4-SA5C (94 pages)
- RCP4W (96 pages)
- RCS2-F5D (142 pages)
- RCS2-GR8 (46 pages)
- RCS2-RN5N (80 pages)
- RCS2-RT6 (60 pages)
- RCS2-SA4C (258 pages)
- RCS2-TCA5N (62 pages)
- RCL-SA1L (66 pages)
- RCL-RA1L (56 pages)
- RCLE-GR5L (46 pages)
- IK Series (16 pages)
- FS (84 pages)
- IF (76 pages)
- ISB (114 pages)
- ISDA (126 pages)
- ISDB (116 pages)
- ISPWA (90 pages)
- ICS(P)A (16 pages)
- NS (78 pages)
- RS (46 pages)