4. Description of Operating Functions

Push & hold operation
It defines the maximum push amount from the target position in the push & hold operation.
Set the positioning band in such a way as to prevent positioning completion before the actuator contacts
work by considering mechanical variations of work.

(8) Zone +/-:It defines the zone where the zone output signal turns ON.

For added flexibility, these parameters can be set separately for each target position.

[Setting example]

No.

Position

[mm]

Zone +

[mm]

Zone –

[mm]

Comment

0 5.00 100.00

0.00

1 380.00

400.00

300.00

2 200.00

250.00

150.00

Movement command to position No. 0

Movement command to position No. 1

Position at which the position complete signal turns ON when the actuator
contacts work and push completion is judged

Speed

Push

speed

Target position

Positioning band (maximum push amount)

Zone output signal

Zone output signal

Home

Target position

+ side limit

Zone output signal

+ side limit

− side limit