IAI America PCON-SE User Manual
Page 58

46
4. Description of Operating Functions
Push & hold operation
It defines the maximum push amount from the target position in the push & hold operation.
Set the positioning band in such a way as to prevent positioning completion before the actuator contacts
work by considering mechanical variations of work.
(8) Zone +/-:It defines the zone where the zone output signal turns ON.
For added flexibility, these parameters can be set separately for each target position.
[Setting example]
No.
Position
[mm]
Zone +
[mm]
Zone –
[mm]
Comment
0 5.00 100.00
0.00
1 380.00
400.00
300.00
2 200.00
250.00
150.00
Movement command to position No. 0
Movement command to position No. 1
Position at which the position complete signal turns ON when the actuator
contacts work and push completion is judged
Speed
Push
speed
Target position
Positioning band (maximum push amount)
Zone output signal
Zone output signal
Home
Target position
+ side limit
Zone output signal
+ side limit
− side limit
- ERC2 (138 pages)
- ERC2 (188 pages)
- ERC3 (438 pages)
- ERC (153 pages)
- RCA-E (53 pages)
- RCA-P (42 pages)
- RCB-101-MW (38 pages)
- RCP2-C (178 pages)
- RCS-E (102 pages)
- RCA-A4R (72 pages)
- RCA-RA3C (114 pages)
- RCA-SRA4R (56 pages)
- RCA2-RA2AC (100 pages)
- RCA2-SA2AC (92 pages)
- RCA2-TA4C (134 pages)
- RCD-RA1D (40 pages)
- RCP2-BA6 (72 pages)
- RCP2-GRSS (130 pages)
- RCP2-HS8C (126 pages)
- RCP2-RA2C (120 pages)
- RCP2-RTBS (80 pages)
- RCP2W-SA16C (46 pages)
- RCP3-RA2AC (60 pages)
- RCP4-RA5C (82 pages)
- RCP4-SA5C (94 pages)
- RCP4W (96 pages)
- RCS2-F5D (142 pages)
- RCS2-GR8 (46 pages)
- RCS2-RN5N (80 pages)
- RCS2-RT6 (60 pages)
- RCS2-SA4C (258 pages)
- RCS2-TCA5N (62 pages)
- RCL-SA1L (66 pages)
- RCL-RA1L (56 pages)
- RCLE-GR5L (46 pages)
- IK Series (16 pages)
- FS (84 pages)
- IF (76 pages)
- ISB (114 pages)
- ISDA (126 pages)
- ISDB (116 pages)
- ISPWA (90 pages)
- NS (78 pages)
- ICS(P)A (16 pages)
- RS (46 pages)