beautypg.com

Pulse rise/fall time (option 1e6 only), Recommended equipment, Equipment setup – Atec Agilent-8563E User Manual

Page 85

background image

Performance Tests

ESG Family Signal Generators

20. Pulse Rise/Fall Time (Option 1E6 only)

4-36

Calibration Guide

20. Pulse Rise/Fall Time (Option 1E6 only)

This test checks the rise/fall time performance of the RF carrier when pulse modulated by
way of the PULSE IN path. The oscilloscope captures the rising or falling edge of the RF
pulse envelope, and calculations are made from the digitized data. Transition time
calculated is for the 10% to 90% portion of the envelope.

Recommended Equipment

• HP/Agilent 54750A Digitizing Oscilloscope

• HP/Agilent 54751A or 54752A Plug-in

• HP/Agilent 33120A Function Generator

• HP/Agilent 8491A/B Opt 010 Attenuator (10 dB)

• HP/Agilent 8491A/B Opt 020 Attenuator (20 dB)

Equipment Setup

Figure 4-33 Pulse Rise/Fall Time Setup (Option 1E6)