Atec Bird-SA Series User Manual
Site analyzer, Ex series
Bird
®
Technologies Group, consisting of Bird
®
Electronic Corporation and TXRX Systems
®
, is a global, innovative supplier of RF products, systems, services and educational solutions.
Bird
®
Technologies Group reserved the right to modify specifications or discontinue any product without notice.
www.bird-technologies.com
440.248.1200/866.695.4569 [email protected]
Site Analyzer
EX Series
SA-6000EX (25-6000 MHz)
SA-2500EX (780-2500 MHz)
SA-1700EX (25-1700 MHz)
SA-1700EXP (25-1700 MHz)
568-EXSeries-1092009
•
One unit covers the entire 25-6000 MHz range!
• Easy to operate and field ready for first-time, occasional and experienced users
• Suitable for use in Worldwide Cellular and PCS/DCS systems; supporting measurement of CDMA, GSM, TDMA and
AMPS modulation schemes
• Other applications include 3G, Broadcast, Government, Tactical Military, Microwave, Paging, Public Safety, Trunking,
WLAN and WLL, and TETRA. See model matrix below
• Color display is clearly visible in direct sunlight
• With a single download you can view data as Distance to Fault or Measurement Match-
no need to store two traces.
• FDR (Frequency Domain Reflectometry) measurement method results in a highly reliable assessment of the health of
critical components in your system; ultimately providing a “heads-up” before a failure occurs
• Fault location or DTF mode indicates VSWR or Return Loss levels at each point along the cable and antenna system
length
• Cable Loss function measures insertion loss of the cable system over a given frequency range
Model #
SA-1700EX
SA-1700EXP
SA-2500EX
SA-6000EX
Frequency Range
25-1700 MHz
25-1700 MHz
780-2500 MHz
25-6000 MHz
Frequency Resolution
25 kHz; 25-800 MHz
25 kHz; 25-800 MHz
50 kHz
25 kHz; 25-800 MHz
50 kHz; 800-1700 MHz
50 kHz; 800-1700 MHz
50 kHz; 800-2500 MHz
150 kHz; 2500-6000 MHz
Power Measurement
No
Yes
Yes
Yes
Return Loss
0 to -60 dB
test Port
N-type female connector
impedance
50
Speed
1 multi-frequency scan (238 points)/2 seconds
1 multi-frequency scan (475 points)/3.5 seconds
1 multi-frequency scan (949 points)/6 seconds
trace Resolution
238 (default), 475, or 949 per trace
Storage Capacity
15 Set-Ups/(500) 238 point traces
immunity to interfering Signals
Rejects on-frequency signals up to +13 dBm
Maximum input Signal
+22 dBm
Data transfer
9-pin RS-232 (DB9), compatible with serial port
internal time
Rechargeable Lithium-Ion batteries. 3-hour minimum operating time.
Auto shut-off conserves battery life.
external DC
9-16 VDC fused, < 3 A
external AC
90 to 264 VAC @ 45-66 Hz; AC/DC adapter required
Operating temperature
-10° to +50° C (+14° to +122° F)
Storage temperature
-40° to +80° C (-40° to +176° F)
Humidity
95% ± 5% max., (non-condensing)
Altitude
Up to 15,000 feet (4572 m)
Dimensions
10.5 ” x 8.4” x 3.3” (265 x 212 x 83 mm)
Weight
5.5 lbs. (2.5 kg)
upgradeable
SA-6000EX
SA-6000EX
SA-6000EX
No