Atec Agilent-N4010A User Manual
Data sheet n4010a introduction
Agilent
N4010A Wireless Connectivity Test Set
and N4011A MIMO/Multi-port Adapter
Data Sheet
N4010A Introduction
The Agilent N4010A wireless connectivity test set is a
measurement solution that enables efficient and lower
cost test for products and components that incorporate
Bluetooth
®
wireless technology, Wireless LAN (WLAN),
and other emerging wireless connectivity technologies.
The Bluetooth (N4010A Option 101) feature set provides
the ability to connect to Bluetooth version 1.1 and 1.2
devices in either test mode or normal mode, and make
measurements in accordance with the Bluetooth RF test
specification. Bluetooth EDR link plus measurements
(Option 107) add BTv2.0+EDR support and enhanced data
rate (EDR) measurement capabilities.
Bluetooth audio generation and analysis (Option 113),
simplifies Bluetooth audio test configurations and provides
cost-effective functional test of Bluetooth audio devices
by performing a basic set of audio measurements. Headset
profile (Option 112) enables testing of Bluetooth voice
channels, audio gateway, and headset products.
The N4017A Bluetooth
®
graphical measurement application,
a PC-based software product, works in a complementary
manner with the N4010A test set and provides the ability
to fully configure the test set and display
both numerical and graphical results.
The Wireless LAN feature set (N4010A Option 102/102)
combines a fully-calibrated vector signal generator and
wide bandwidth signal analyzer into a single test set,
which enables efficient and repeatable WLAN module
test from R&D through to production. N4010A Option 108
provides the software license for the 802.11n MIMO
modulation analysis measurements within the test set.
The N4010A test set also works with the Agilent 89601A
and 89607A vector signal analyzer software. This software
provides the flexibility to make a broad range of measure-
ments for evaluating wireless formats in the 2.4 GHz or
5 GHz band, including ZigBee/IEEE 802.15.4.
The test set will meet its warranted performance after
one hour within the stated environmental operating range
plus 40 minutes after turn on. Unless otherwise stated, all
specifications are valid over the temperature range 20 to
30 °C. Supplemental characteristics are intended to provide
additional information, useful in applying the instrument by
giving typical (expected), but not warranted, performance
parameters. These characteristics are shown in italics or
labeled as nominal.