Dataproducts submenu, Data bit 8, Pi ignored – Printronix P7000 Cartridge Ribbon Printer User Manual
Page 95: Data polarity
Dataproducts Submenu
95
Dataproducts Submenu
Data Bit 8
•
Enable
(default). Allows access to the extended ASCII character set.
•
Disable
. The printer interprets bit 8 of each incoming data character as a
zero, regardless of its actual setting.
PI Ignored
The PI (Paper Instruction) signal is used to control vertical paper motion.
•
Enable
(default). Causes the printer to interpret the eight data lines as
DVFU commands when the PI signal is true.
•
Disable
. Ignores the PI signal and treats the data as characters or control
codes.
Data Polarity
The Data Polarity parameter must be set to match the data polarity of your
host computer.
•
Standard
(default). Does not expect the host computer to invert the data.
•
Inverted
. Expects the data received on the data lines from the host
computer to be inverted. Ones become zeros, and zeros become ones.
Dataproducts
Data Bit 8
PI Ignored
Data
Polarity
Resp.
Polarity
Latch Data
On
Prime Signal
TOF Action
Buffer Size
in K
1
Enable*
Disable
Enable*
Disable
Standard*
Inverted
Standard*
Inverted
Middle*
Trailing
Leading
Disable*
Enable
Reset*
Do Nothing
16*
(1-16)
* = Factory Default
1
OpenPrint HD products have an extended range to 256.
Auto
Trickle
Disable*
Enable
Trickle
Time
1/4 sec*
1/2 sec
1 sec
2 sec
4 sec
8 sec
16 sec
Off