PTX Transparent

Lead-in Chars

You can enable additional features that are not available in standard Twinax
emulations. To access these features, send text commands in the data
stream. The commands must have a start and end code. Three sets (each
containing a start and end code) are available:

Set 1

. start code: <%

stop code: >

Set 2

. start code:

¬¬

stop code: $

Set 3

. start code: _%

stop code: _

User Defined

Usr Defined HTRN

This option is used in Twinax SPC emulation. The range is ASCII character.
This option allows users to define ther own lead-in characters for the
Printronix Specific commands. Select a hex value for the following codes for
the User Defined option:

Start Code 1 5F

Start Code 2 5F

Stop Code 5B

Alt. Set 80-9F

Printable

(default). Prints data in the range of hex 80 through hex 9F.

Control Code

. Interprets data in the range of hex 80 through hex 9F as a

control code.

Graphic Chek Err

Allows overriding of the host setting for the SGEA (Set Graphic Error Action)
command. For more information about the SGEA command, refer to the

Coax/Twinax Programmer's Reference Manual

.

Enable

(default). The host setting for the SGEA used by the printer. If the

SGEA command is requested to stop on graphic errors, the printer will
stop when a graphic error is detected.

Disable

. Ignores the SGEA command from the host. The printer does not

stop when an error is detected; instead, it substitutes the character
selected in the Graphic Chek Code parameter.