Display functions, Line terminator, Ptx linefeed – Printronix P7000 Cartridge Ribbon Printer User Manual
Page 232: Lpi adjust, Page l./lines, Page l./inches
232
Chapter
4
PCL - II Emulation
Display Functions
•
Disable
(default). Control characters are not printed.
•
Enable
. Control characters are printed before they get executed. This is a
useful debugging tool.
Line Terminator
You can define the action of the line. Four options are available: LF after CR,
CR after LF, CR after FF, and CR after VT. Each of these options may be
enabled or disabled independent of one another.
PTX Linefeed
•
Disable
(default). Linefeed is to be performed as calculated from the
bottom of the graphics or barcode, thereby disrupting the vertical text
alignment.
•
Enable
. The Linefeed moves to the next line as calculated from the Top
of Form position, thereby retaining vertical text alignment. When printing
graphics or bar codes, you may want to set the PTX Linefeed parameter
to Enable to maintain text alignment.
LPI Adjust
This parameter lets you specify the lines per inch (lpi) values: 6 LPI (default)
or 8 LPI.
Page L./Lines
This parameter lets you set physical page length in lines from 12 to 96 at 6 lpi,
or 16 to 128 at 8 cpi. The default is 66 lines at 6 lpi.
NOTE:
If 6 lpi is selected, you will be able to scroll the menu to 128 (an
invalid length). However, when you press ENTER to select this value,
the menu will return with the maximum lines for 6 lpi (i.e., 96 lines).
Similarly, selecting too few lines for 8 lpi will cause the menu to return
with 16 lines.
Page L./Inches
This parameter allows you to set physical page length from 2 to 16 inches, in
increments of half an inch. The default is 11 inches.
Linefeed
LINE 1
Linefeed
LINE 2
LINE 3
LINE 1
LINE 2
LINE 3
PTX Linefeed Enabled
PTX Linefeed Disabled