beautypg.com

Pos. on bc/ovrsz, Bc check digit, Barcode darkmode – Printronix P7000 Cartridge Ribbon Printer User Manual

Page 194: Pum default, Truncate pi slew, Etx/ack

background image

194

Chapter

4

ANSI Emulation

Pos. on BC/OvrSz

Set to top

(default). The paper is fed back to the top of barcodes or

oversized characters after they are printed. This allows printing on the
same line.

Set to bottom

. The printer will continue printing without backing up.

BC Check Digit

By host

(default). The host calculates the barcode check digit and sends

it along with the barcode. The check digit is not verified by the printer but
printed as it was received.

By printer

. The barcode is sent without the check digit, and the printer

calculates and adds it in.

Barcode Darkmode

Enable

(default). The barcodes are printed at a higher resolution.

Disable

. The barcodes are printed at lower resolution but at a higher

speed.

PUM Default

This is the Unit of Measure (UOM) as it is used within the ANSI emulation.
Coordinates received in ESC sequences can be sent in two UOMs:

Decipoints

(default). A unit of 1/720 inch

Lines or columns

. Uses the current LPI and CPI values.

The UOM used is determined by this configuration setting.

Truncate PI Slew

Truncate at TOF

(default). The slew is terminated when the next Top-of-

Form is reached. (This function applies to the ANSI EVFU only.)

Disable

. PI slews will be completed independent of their length.

ETX/ACK

End of Text/Acknowledge. The host controls the flow of communcation to the
printer by sending a block of data and ending the block with an End of Text
(ETX) signal. When the printer receives the ETX signal, it acknowledges the
ETX, thereby acknowledging it has received the entire block of data.

Disable

(default)

Immediate

Afterprint