Buffer reprint, Spc null supp, Spc space supp – Printronix P7000 Cartridge Ribbon Printer User Manual
Page 154: Nl at mpp+1
154
Chapter
4
Coax/Twinax (CTHI) Emulation
PA2
PA2 is only valid when the printer is in the OFFLINE state and the Coax SCS
data stream is active. This function displays the “PA2 ENABLED” message
when the ENTER key is pressed and sends a special operator request to the
host when the printer is placed ONLINE.
Buffer Reprint
This option is valid only when the printer is printing in SCS mode. When the
ENTER key is pressed, “Buffer Reprint Enabled” is displayed and an
Intervention Required status is sent to the host. Pressing ENTER again
cancels the Buffer Reprint function and “Buffer Reprint Disabled” is displayed.
SPC Null Supp
•
Enable
(default). Treats nulls as blank spaces.
•
Disable
. Ignores nulls. The print position does not move.
SPC Space Supp
This option is only available in Coax SPC emulation and is used in LU3/DSC/
DSE mode only.
•
Disable
(default). Treats nulls and spaces normally.
•
Enable
. If the entire line consists of spaces and nulls, the line will be
discarded.
NL At MPP+1
Controls how many lines are skipped when the carriage returns to a new line.
•
On
(default). Moves to the first print position two lines down from the
current position.
•
Off
. Moves to the first print position of the next print line.