Ieee 1284 parallel (bidirectional) submenu, Prime signal, Tof action – Printronix P7000 Cartridge Ribbon Printer User Manual
Page 90: Buffer size in k, Chapter 4
![background image](/manuals/268580/90/background.png)
90
Chapter
4
HOST INTERFACE Menu
IEEE 1284 Parallel (Bidirectional) Submenu
The IEEE 1284 interface is faster and more versatile than Centronics and
supports bidirectional communication. Configuration of this interface is
controlled from the host. Refer to
for more details about the available modes (Compatibility,
Nibble, and Byte).
Prime Signal
•
Enable
(default). The parallel port will perform a warm start (reboot) if the
host asserts the prime signal.
•
Disable
. The parallel port will not perform a warm start (reboot) if the host
asserts the prime signal.
TOF Action
•
Reset
(default). A form feed is performed before a warm start when the
prime signal is asserted from the host. This setting is used only if the
prime signal parameter is enabled.
•
Do Nothing
. Nothing occurs before a warm start when the prime signal is
asserted from the host.
Buffer Size in K
This option configures the amount of memory allocated for the IEEE 1284
parallel port buffer. You can specify between 1 and 16 Kbytes, in 1-Kbyte
increments. The default is 16K.
NOTE:
OpenPrint HD products have a range of 1 to 256 and a default of 64K.
IEEE 1284
(from page 87)
Prime
Signal
TOF
Action
Buffer Size
in K
1
Enable*
Disable
Reset*
Do Nothing
16*
1-16
* = Factory Default
1
OpenPrint HD products have an extended range to 256.
Auto
Trickle
Disable*
Enable
Trickle
Time
1/4 sec*
1/2 sec
1 sec
2 sec
4 sec
8 sec
16 sec
Off
Offline
Process
Disable*
Enable