Chapter

4

Coax/Twinax (CTHI) Emulation

FF Validity

Determines if the position of a form feed command affects its execution.

Off

(default). Performs a form feed only if it occurs at the first print

position in a line or at Maximum Print Position +1. A form feed command
at any other position is recognized as a space.

On

. Allows the printer to perform a form feed command anywhere in the

data stream.

Auto Skip At End

Specifies whether or not to perform an automatic form feed at the end of a
print buffer. If form feed is the last character in the print order, the form feed
function is supplied by the Auto Skip At End option.

Off

(default). Sets the printer to print at print position 1 of the next line.

On

. Sets the printer to print at print position 1 of the first line of the next

form.

FF After Job

Determines the print position after an operator-initiated local copy (print
screen function).

Off

(default). Performs an automatic new line command after completing

a print buffer (unless a new line, form feed, or carriage return command
was the last one executed). The printer is set to print at print position 1 of
the next line.

On

. Performs an automatic form feed command unless a form feed was

the last one executed. The printer is set to print at print position 1 of the
first line on the next form.

CR, EM, and NL (3287 only)

CR (Carriage Return), EM (Error Message), and NL (New Line) specify that
the printer treat the CR, EM, and NL control codes either as spaces or as
control codes.

On

(default). Treats the CR, EM, and NL commands as control codes.

Off

. Treats the CR, EM, and NL commands as spaces.

Host Override

Determines whether the printer accepts certain commands sent by the host,
or continues to use the current operator panel settings.

Disable

(default). Allows these host commands to override operator

panel settings: line length, forms length, lines per inch (LPI), characters
per inch (CPI), print quality, and text orientation. Note the information
appearing on the message display may not match the data stream
setting. No values will change upon initial selection of the disable option.

Enable

. The operator panel settings override the host commands.