Configure user lines – Xantrex Technology XDC 20-600 User Manual
Page 89
![background image](/manuals/229298/89/background.png)
Power Supply Operation
TM-XDOP-01XN
3–27
Configure User Lines
The USER LINES menu option lets you configure the auxiliary status lines
The Auxiliary (Aux) lines are 2 open collector outputs that can be used to monitor
the status of the power supply. The auxiliary lines are referred to as AUX A and
AUX B. See “Making Connections for Remote Control” on page 4–3 for details.
Each user line also has a corresponding annunciator on the front panel display to
indicate when it is on. Aux lines can be set up to report the following status
conditions:
•
None
•
Unregul: Output Unregulated
•
OVP: Over-Voltage Condition
•
UV: Under-Voltage Condition
•
OC: Over-Current Condition
•
UC: Under-Current Condition
•
OP: Over-Power Condition
•
UP: Under-Power Condition
•
AC Off: Input power has failed or is out of range
•
OTP: Over-Temperature Condition
•
Hi Temp: High-Temperature Condition
•
SenseProt: Sense Protection Tripped
•
Fold Prot: Fold Protection Tripped
•
CC: Constant Current Mode
•
CV: Constant Voltage Mode
•
CP: Constant Power Mode
•
Out ON: Output On
•
Out OFF: Output Off