beautypg.com

Xantrex Technology XDC 20-600 User Manual

Page 239

background image

S

C

PI C

o

mmand S

u

mmary

TM-XDOP-01XN

C

–15

Set High Current
Limit

[[:]SOURce][]:CURRent:LIMit:HIGH

{|MAXimum|MINimum}

Set upper limit of current setpoint
range (soft limits)

Yes

Set Low Current
Limit

[[:]SOURce][]:CURRent:LIMit:LOW

{|MAXimum|MINimum}

Set lower limit of current setpoint
range (soft limits)

Yes

Set High Power
Limit

[[:]SOURce][]:POWer:LIMit:HIGH

{|MAXimum|MINimum}

Set upper limit of power setpoint
range (soft limits)

Yes

Set Low Power
Limit

[[:]SOURce][]:POWer:LIMit:LOW

{|MAXimum|MINimum}

Set lower limit of power setpoint
range (soft limits)

Yes

Set High Voltage
Limit

[[:]SOURce][]:VOLTage:LIMit:HIGH

{|MAXimum|MINimum}

Set upper limit of voltage setpoint
range (soft limits)

Yes

Set Low Voltage
Limit

[[:]SOURce][]:VOLTage:LIMit:LOW

{|MAXimum|MINimum}

Set lower limit of voltage setpoint
range (soft limits)

Yes

Table C-4 Commands for Current Share

Function

SCPI Command

Description

Query

Set Current Sharing
Mode

[[:]SOURce][]:COMBine:CSHare:MODE

{NONE|MASTer|SLAVe}

Select current share mode

Yes

Read Summed
Current

[:]MEASure[:SCALar]:CURRent[:DC]? SUM

Read total current output of all
current sharing supplies

N/A

Table C-3 Commands for Output Control

Function

SCPI Command

Description

Query