Xantrex Technology XDC 20-600 User Manual
Page 166

Remote Operation
4–52
TM-XDOP-01XN
Table 4-15 QUEStionable Status Register
Bit
Bit Weight
Bit Name
Description
0
1
VOLTage Summary
Reflects a summary of the VOLTage Sub-Register.
1
2
CURRent Summary
Reflects a summary of the CURRent Sub-Register.
2
4
TIME Not
implemented
3
8
POWer Summary
Reflects a summary of the POWer Sub-Register.
4
16
TEMPerature Summary
Reflects a summary of the TEMPerature Sub-Register.
5
32
FREQuency Summary
Not implemented
6
64
PHASe Summary
Not implemented
7
128
MODulation Summary
Not implemented
8
256
CALibration
Indicates an error in the unit calibration.
9
512
Not Used
Not implemented
10
1024
Not Used
Not implemented
11
2048
AC Off
Indicates an AC Supply failure.
12
4096
UNRegulated
Indicates that the output is not regulated in either Constant
Voltage mode, Constant Current mode or Constant Power
mode. Reflects the inverse of the Operation Regulation
Summary bit.
13
8192
INSTrument Summary
Not implemented
14
16384
Command Warning
Not implemented
15
32768
Not Used
Always zero
TM-XDOP-01XN.book Page 52 Monday, July 17, 2006 11:19 AM