Power On Output State

You may also change the output state whether the output is enabled or disabled at
power on.

To change the power on at output state:

OUTP:PON:STAT [ON|OFF|1|0]

To check the setting:

OUTP:PON:STAT?

Reset

Resetting the unit puts certain features to a known state. These states are listed in
the table below.

To reset the unit:

*RST or SYST:RES

Table 4-8 Features Affected by Reset (*RST) Command

Feature

Reset State (*RST)

Voltage setpoint

0.0V

Current setpoint

0.0A

Power setpoint

103% of power rating

Low voltage setpoint limit

0.0V

High voltage setpoint limit

103% of voltage rating

Low current setpoint limit

0.0A

High current setpoint limit

103% of current rating

Low power setpoint

0% of power rating

High power setpoint

103% of power rating

Over voltage protection

Disabled (0.0V)

Under voltage protection

Disabled (0.0V) and not shutdown when tripped

Over current protection

Disabled (0.0A) and not shutdown when tripped

Under current protection

Disabled (0.0A) and not shutdown when tripped

Over power protection

Disabled (0.0W) and not shutdown when tripped

Under power protection

Disabled (0.0W) and not shutdown when tripped

Fold shutdown protection

None and delay 0.5s

AC off shutdown recovery

Autorecover

Over temperature shutdown
recovery

Latched

Triggered voltage setpoint

Disabled (Default)

Triggered current setpoint

Disabled (Default)

TM-XDOP-01XN.book Page 24 Monday, July 17, 2006 11:19 AM