beautypg.com

Xantrex Technology XDC 20-600 User Manual

Page 160

background image

Remote Operation

4–46

TM-XDOP-01XN

Table 4-9 OPERation Status Register

Bit

Bit Weight

Bit Name

Description

0

1

CALibrating

Indicates that the supply is in CALibration Mode.

1

2

SETTling

Not implemented

2

4

RANGing

Not implemented

3

8

SWEeping

Not implemented

4

16

MEASuring

Not implemented

5

32

Waiting for TRIGger
Summary

Indicates if the supply is waiting for a TRIGger.

6

64

Waiting for ARM Summary

Not implemented

7

128

CORRecting

Not implemented

8

256

REGulating Summary

Reflects the summary of the REGulating Sub-Register.

9

512

SHUTdown Summary

Reflects the summary of the SHUTdown Sub-Register.

10

1024

Remote CONtrol Summary

Reflects the summary of the Remote CONtrol Sub-
Register.

11

2048

Current SHareSummary

Reflects the summary of the Current Share Sub-
Register.

12

4096

Not Used

Not used

13

8192

INSTrument Summary

Not implemented

14

16384

PROGram Running

Indicates that an Automated Sequence is running.

15

32768

Not Used

Not used

TM-XDOP-01XN.book Page 46 Monday, July 17, 2006 11:19 AM