Power Supply Operation
TM-XDOP-01XN
3–47
To set the current limits:
Step # Do This
You Will See
1
ERROR MSGS
2
until you see the “SETPT LIMIT”
option
SETPT LIMIT
3
Voltage Limit
4
Current Limit
5
High 0A
6
Use the Current knob, arrow keys, or
numeric keypad to enter a value. The value
must be within 0A to 103% of the unit’s
rated current and must be higher than the
current setpoint.
High #####A
7
Low 0A
The Maximum setting is
saved and the Minimum
setting appears.
8
Use the Voltage knob, arrow keys, or
numeric keypad to enter a value. The value
must be within 0A to 103% of the unit’s
rated current and must be lower than the
current setpoint.
Low #####A
9
The setting is saved and
the display returns to its
default operating mode.