Editing trigger source of a sequence – Xantrex Technology XDC 20-600 User Manual
Page 103
![background image](/manuals/229298/103/background.png)
Power Supply Operation
TM-XDOP-01XN
3–41
Editing Trigger Source of a Sequence
When steps are programmed to advance step by trigger, this option allows you to
edit the source of those trigger events.
To edit the sequence’s trigger source:
Step #
Do This
You Will See
1
ERROR MSGS
2
6 times or
.
AUTO SEQ PGM
3
Sequence 1
4
or
. Use the scroll keys to
select a sequence to work with.
Sequence #
5
Edit
Sequence
6
or
. Use the scroll keys to
select the Trig Source option.
Trig Source
7
Trig From Man
8
or
. Use the scroll keys to
select the trigger source:
•
Man is triggered by pressing the trigger
key.
•
Ext is triggered by the rear external trigger
line.
•
Imm is triggered by receiving an
INIT:IMM command
•
Bus is triggered by a GPIB GET command
or a *TRG command.
Trig from ###
9
Edit Sequence
10
The sequence’s trigger source has now been
changed. Select another sequence to work with
or escape by pressing
MENU
MENU
ENTER
ENTER
ENTER
ENTER
EXIT