Xantrex Technology XDC 20-600 User Manual
Page 162
![background image](/manuals/229298/162/background.png)
Remote Operation
4–48
TM-XDOP-01XN
Protection SHUTdown Sub-Register
Table 4-12 Protection SHUTdown Sub-Register
Bit
Bit Weight
Bit Name
Description
0
1
Over VOLTage
Over voltage protection has tripped
1
2
Under VOLTage
Under voltage protection has tripped
2
4
Over CURrent
Over current protection has tripped
3
8
Under CURrent
Under current protection has tripped
4
16
Over POWer
Over power protection has tripped
5
32
Under POWer
Under power protection has tripped
6
64
AC Off
AC Off protection has tripped
7
128
Over TEMPerature
Over temperature protection has tripped
8
256
SENSe
Sense protection has tripped
9
512
FOLDback
Foldback protection has tripped
10
1024
ASlave
12000 Watt Analog slave has shutdown due to a protection event
in the slave unit