Remote Operation

4–30

TM-XDOP-01XN

Over-Current Protection

T

o set the Over-Current Protection level:

SOUR:CURR:PROT

SOUR:CURR:PROT:STAT

The first OCP protection command sets the protection level. The second
command lets you choose a warning alarm only [OFF] or shut down with an alarm
[ON] if the protection level is exceeded.

To check the Over-Current Protection level:

SOUR:CURR:PROT?

To check if the Over-Current Protection was tripped:

SOUR:CURR:PROT:TRIP?

Under-Current Protection

To set the Under-Current Protection level:

SOUR:CURR:PROT:UND

SOUR:CURR:PROT:UND:STAT

The first UCP protection command sets the protection level. The second
command lets you choose a warning alarm only [OFF] or shut down with an alarm
[ON] if the protection level is exceeded.

To check the Under-Current Protection level:

SOUR:CURR:PROT?

To check if the Under-Current Protection was tripped:

SOUR:CURR:PROT:TRIP?