Power Supply Operation

TM-XDOP-01XN

3–17

The possible alarms are:

Shutdown vs Protection Alarm

If a protection setpoint is exceeded, the system does the following:

1. If S/D if tripped? Y has been selected, the unit shuts down.

If it is an OVP alarm, the unit shuts down.

2. If S/D if tripped? N has been selected, and it is not an OVP alarm, the

unit does not shut down but does create an alarm message.

3. If the unit is not shutting down, the system still sets the appropriate status bits

in the questionable status register, which can be queried remotely. See “Status
Registers” on page 4–43 for more information.

OVP Shutdown

UVP Shutdown

OCP Shutdown

UCP Shutdown

OPP Shutdown

UPP Shutdown

UVP Alarm

OCP Alarm

UCP Alarm

OPP Alarm

UPP Alarm

Fold Shutdown

Sense Shutdown

Hi Temp Alarm

OTP Shutdown

AC Off

Slave Shutdown Alarm (12000 Watt only)