beautypg.com

Xantrex Technology XDC 20-600 User Manual

Page 256

background image

SC
PI Co

mmand Re

fe

ren
ce

C–32

TM-XDOP-01XN

Table C-15 Legacy Commands

Function

SCPI Command

Description

Query

Reset

CLR

Equivalent to *RST and SYSTem:RESet commands
Performs a device reset. Set the power supply to a known state that is
independent of the use history of the device

N/A

Query System Error

ERR?

Equivalent to SYSTem:ERRor? command except that the return string
contains the command
Returns the next error in the instrument’s error queue

N/A

Identification Query

ID?

Query identification string. (Model ID and Version)

N/A

Read Output
Current

IOUT?

Equivalent to MEASure:CURRent? command
Read output current

N/A

Set High Current
Limit

IMAX

Equivalent to SOURce:CURRent:LIMit:HIGH command.
Set upper limit of current setpoint range (soft limits)

Yes

Set (Immediate)
Current Setpoint

ISET

Equivalent to SOURce:CURRent command.
Change current setpoint

Yes

Set Output State

OUT

state>

Equivalent to OUTP command.
Enable/disable the power supply output

Yes

Set Over Voltage
Protection Level

OVSET

Equivalent to SOURce:VOLTage:PROTection:OVER:LEVel
command.
Set the over voltage protection level

Yes

ROM Query

ROM?

Queries the main firmware version

N/A

Clear Output
Protection

RST

Equivalent to OUTPut:PROTection:CLEar command.
Clears the protection mechanism

N/A

Set High Voltage
Limit

VMAX

Equivalent to SOURce:VOLTage:LIMit:HIGH command.
Set upper limit of voltage setpoint range (soft limits)

Yes

Read Output
Voltage

VOUT?

Equivalent to MEASure:VOLTage? command.
Read output voltage

N/A

Set (Immediate)
Voltage Setpoint

VSET

Equivalent to SOURce:VOLTage command.
Change voltage setpoint

Yes

TM-XDOP-01XN.book Page 32 Monday, July 17, 2006 11:19 AM