Chapter 5 Configuring IPmux-11 for a Typical Application
Installation and Operation Manual
5-4
Configuring IPmux-11 Units
IPmux-11 Ver. 2.00
Configuring Bundles
To assign timeslots to a bundle:
1. Display the Connection menu (Configuration > Connection), and assign a
number 1 to a bundle.
2. Display the DS0 Bundle Configuration menu (Configuration > Connection >
DS0 bundle
), and assign timeslots 1 to 10 to bundle 1.
Configuration>Connection>DS0 bundle configuration
+1 +2 +3 +4 +5 +6 +7 +8 +9 +10
TS 0 1 1 1 1 1 1 1 1 1 1
TS 10 0 0 0 0 0 0 0 0 0 0
TS 20 0 0 0 0 0 0 0 0 0 0
TS 30 0
1. Change cell [0 - 1] ... (0)
>
Please select item <1 to 1>
E - Enable All; L - Disable All
ESC-prev.menu; !-main menu; &-exit; ?-help 1 Mngr/s
Figure 5-5. Assigning Timeslots to a Bundle
To connect the bundles:
1. Display the Bundle Connection Configuration menu (Configuration >
Connection
> Bundle connection) and configure the following parameters:
Destination IP address for IPmux-11 (A) bundle –192.168.10.1
Destination IP address for IPmux-11 (B) bundle – 192.168.10.2
Connection status – Enable
Destination bundle – 1
Jitter buffer – 5 msec
OAM Enabled.
2. Leave all other parameters with their default values.