The maximum permissible current capability of the branch distribution circuit that supplies power to the
product is 16A. The circuit breaker in the building installation should have high breaking capacity and must
operate at short-circuit current exceeding 35A.
Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate the
circuit breaker of the panel board that services the equipment and switch it to the OFF position. When
connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the
positive pole and last the negative pole. Switch the circuit breaker back to the ON position.
A readily accessible disconnect device that is suitably rated and approved should be incorporated in the
building installation.
If the DC mains are floating, the switch must disconnect both poles simultaneously.

Connection of Data and Telecommunications Cables

Data and telecommunication interfaces are classified according to their safety status.
The following table lists the status of several standard interfaces. If the status of a given port differs from
the standard one, a notice will be given in the manual.

Ports Safety

Status

V.11, V.28, V.35, V.36, RS-530,

X.21, 10 BaseT, 100 BaseT,
Unbalanced E1, E2, E3, STM, DS-2,

DS-3, S-Interface ISDN, Analog voice

E&M

SELV Safety Extra Low Voltage:

Ports which do not present a safety hazard. Usually

up to 30 VAC or 60 VDC.

xDSL (without feeding voltage),
Balanced E1, T1, Sub E1/T1

TNV-1 Telecommunication Network Voltage-1:

Ports whose normal operating voltage is within the

limits of SELV, on which overvoltages from

telecommunications networks are possible.

FXS (Foreign Exchange Subscriber)

TNV-2 Telecommunication Network Voltage-2:

Ports whose normal operating voltage exceeds the

limits of SELV (usually up to 120 VDC or telephone

ringing voltages), on which overvoltages from

telecommunication networks are not possible. These

ports are not permitted to be directly connected to

external telephone and data lines.

FXO (Foreign Exchange Office), xDSL
(with feeding voltage), U-Interface

ISDN

TNV-3 Telecommunication Network Voltage-3:

Ports whose normal operating voltage exceeds the

limits of SELV (usually up to 120 VDC or telephone

ringing voltages), on which overvoltages from

telecommunication networks are possible.


Always connect a given port to a port of the same safety status. If in doubt, seek the assistance of a

qualified safety engineer.
Always make sure that the equipment is grounded before connecting telecommunication cables. Do

not disconnect the ground connection before disconnecting all telecommunications cables.