Table 3-1 – RAD Data comm IPmux-11 User Manual

Page 48

background image

Chapter 3 Operation

Installation and Operation Manual

3-2

Controls and Indicators

IPmux-11 Ver. 2.00

Table 3-1. IPmux-11 LEDs and Controls

Name Type Function

Location

PWR

Green LED

ON – Power is ON

Front panel

ALM

Red/yellow
LED

ON (red) – Active alarm is stored in the log file
ON (yellow) – An alarm is present in the log file
OFF – No alarms are stored in the log file

Front panel

E1 SYNC

Red/green

LED

ON (green) – E1 link is synchronized
ON (red) – E1 link has lost synchronization
OFF – E1 link is disabled

Front panel

T1 SYNC

Red/green

LED

ON (green) – T1 link is synchronized
ON (red) – T1 link has lost synchronization
OFF – T1 link is disabled

Front panel

ETH
LINK/ACT 1

Green LED

ON – Network Ethernet link is OK
Blinks – Data is being transmitted and received on the network

Ethernet link

Front panel

ETH

LINK/ACT 2

Green LED

ON – User Ethernet link 1 is OK
Blinks – Data is being transmitted and received on the user

Ethernet link 1

Front panel

ETH
LINK/ACT 3

Green LED

ON – User Ethernet link 2 is OK
Blinks – Data is being transmitted and received on the user

Ethernet link 2

Front panel

EXT CLK

Red/green

LED

ON (green) – IPmux-11 is configured to external clock and valid

clock input is detected

ON (red) – IPmux-11 is configured to external clock and no valid

clock input is detected

OFF – IPmux-11 is not configured to external clock or the unit is

off

Rear panel

SET DEF

Button

Restores default values

Rear panel