beautypg.com

Table 1-12, Table 1-13 – RAD Data comm IPmux-11 User Manual

Page 34

background image

Chapter 1 Introduction

Installation and Operation Manual

1-20

Functional Description

IPmux-11 Ver. 2.00

Table 1-12. Mode C

Ingress Egress

If a tagged frame enters the transparent port, it

is switched to the tagged port

• If the tagged port is not a member of the frame’s VID,

the frame is discarded

• The tagged port is a member of the frame’s VID, the

frame is transmitted unmodified (tagged)

• If a tagged frame enters the tagged port,

which is not a member of its VID, the frame

is discarded

• If a tagged frame enters the tagged port,

which is a member of its VID, the frame is

switched to all other members

The transparent port transmits the frame unmodified
(tagged)

If an untagged frame enters the transparent port,

it is switched to the tagged port

• If the tagged port is not a member of the transparent

port default VID, the frame is discarded

• If the tagged port is a member of the transparent port

default VID, it adds tag (VID is the transparent port

default VID and PRI is the transparent port default

PRI), and transmits the frame tagged

• If an untagged frame enters the tagged port,

which is not a member of its default VID, the
frame is discarded

• If an untagged frame enters the tagged port,

which is a member of its VID, the frame is
switched to all other members

The transparent port transmits the frame unmodified

(untagged).

Table 1-13. Mode D

Ingress Egress

If a tagged frame enters an untagged port, it is
switched to the other untagged port

The untagged port removes the tag, andtransmits the
frame untagged

If an untagged frame enters an untagged port, it

is switched to the other transparent port

The untagged port transmits the frame unmodified

(untagged)