Chapter 4 Configuration

Installation and Operation Manual

4-6

Configuring IPmux-11 for Management

IPmux-11 Ver. 2.00

It is possible to set up a local or remote management link using the manager
location and VLAN configuration. Refer to the configuration example at the end of

this section.

Network-Eth1 – The network manager accesses IPmux-11 via the

network port (Ethernet port 1)

User1-Eth2 – The network manager accesses IPmux-11 via the user port

1 (Ethernet port 2)

User2-Eth3 – The network manager accesses IPmux-11 via the user port

2 (Ethernet port 3).

Select Link up/down trap, and choose On to enable the management
station to receive a trap when a link failure (link down) or link recovery (link
up) occurs. Choose Off to disable Link Up/Down trap.

Select Alarm trap, and choose On or Off to enable or disable sending

alarm trap to the manager station.

On – The alarm trap is sent to the management station informing of any

alarm which is not masked (see

Masking Alarms

in Chapter 6). Both

entry and exit from an alarm state are declared.

Off – No alarm trap is sent to the management station, even if the alarm

is masked.

Select VLAN tagging, and choose On or Off to consider or ignore the VLAN
tagging of the management traffic coming from the management station.

Select VLAN ID, and enter the ID of the management station VLAN

(1–4095).

Select VLAN priority, and enter the priority of the management station
VLAN (0–7).

Configuration>System>Management>Manager list

1. Manager IP address ... (0.0.0.0)

2. Manager location ... (Empty)

3. Link up/down trap (On)

4. Alarm trap (Off)

5. VLAN tagging (Off)

6. VLAN ID ... (0)

7. VLAN priority ... (0)


>


Please select item <1 to 7>
ESC-prev.menu; !-main menu; &-exit 1 Mngr/s

Figure 4-5. Manager List Menu