RAD Data comm IPmux-11 User Manual
Page 39

Installation and Operation Manual
Chapter 1 Introduction
IPmux-11 Ver. 2.00
Technical Specifications
1-25
Timing
Transmit
• Internal
• External input or output via dedicated connector:
E1/T1 or 2048/1544 kHz squarewave (RS-485
electrical levels)
• Loopback
• Adaptive
Pseudowire
Connections
Number of
Connections
1
Jitter Buffer Size
3–300 msec with 1 msec granularity
Management
Methods
• SNMPv1
• Telnet
• RADview Service Center TDMoIP (ordered separately)
• ASCII terminal via V.24 (RS-232) DCE port
Diagnostics
Loopbacks
• E1/T1 local loopback
• E1/T1 remote loopback
• T1 Facility Type 1 (FAC1) in-band remote loopback
Statistics
E1/T1
As per G.826 and RFC 2495
Ethernet
As per RFC 2819
Receive Buffer
Indication
Overflow, underflow, sequence error
Indicators
General
PWR (green) – Power status
ALM (red/yellow) – Alarm status
EXT CLK (red/green) – External clock status
E1
E1 SYNC (red/green) – E1 synchronization
T1
T1 SYNC (red/green) – T1 synchronization
Ethernet
LINK/ACT (green) – Link/activity status
Power
AC/DC Source
100–240 VAC or -40/-60 VDC
Power
Consumption
8W max
Physical
Height
43.7 mm (1.72 in)
Width
217 mm (8.55 in)
Depth
170 mm (6.7 in)
Weight
0.5 kg (1.1 lb)
Environment
Temperature
0°C to 50°C (32°C to 122°F)
Humidity
Up to 90%, non-condensing