CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier®
Revision 7
Front Panel Operation
MN/CDMQX.IOM
5–32
CONFIG: Frame
Æ EDMAC, EDMAC-2 Æ AUPC+EDMAC Æ Master
 Distant-end Base Address 
 0240 (◄ ►,▲ ▼,ENT) 
To edit the address of the distant-end modem to which this unit will pass messages, first 
select the digit to be edited using the ◄ ► arrow keys, then edit the value of that digit by 
using the ST arrow keys. Press 
ENTER
when done. The valid range of addresses is
from 10 to 9990.
Note: There is a restriction on values that can be entered here – they may only be entered 
in increments of 10. This has been implemented so that a single MASTER may pass 
messages for up to 10 devices at the distant end – this is automatically taken care of, as 
the user may not edit the last digit of the address. 
CONFIG: Frame
Æ EDMAC, EDMAC-2 Æ AUPC+EDMAC Æ Slave
 Address of this Slave 
 Unit: 0241 (◄ ►,▲ ▼,ENT) 
To edit the address of the Slave unit, first select the digit to be edited using the ◄ ► 
arrow keys, then edit the value of that digit by using the ST arrow keys. Press 
ENTER
when done. The valid range of addresses is from 1 to 9999, although ‘base 10' values will 
be automatically skipped. 
Remember that this is a unit that is intended for location at the distant-
end of a link, and will therefore be under the control of a MASTER at the 
other end. This is the equivalent of putting the unit into Remote Control 
mode – no local control is possible. 
5.4.5.3 CONFIG: Frame
Æ D&I++
 Drop & Insert: EDMAC 
 Drp-CH/TS Ins-CH/TS (◄ ►, ENT) 
Select Drp-CH/TS or Ins-CH/TS using the ◄ ► arrow keys, then press
ENTER
. Note the
following:
Drp-CH/TS
Displays the Tx Data Rate
Ins-CH/TS
Displays the Rx Data Rate