7 monitor: odu, 1 monitor: odu ( buc, 2 monitor: odu ( lnb – Mocomtech CDM-QX User Manual
Page 115: 1 monitor: odu æ buc, 2 monitor: odu æ lnb

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier®
Revision 7
Front Panel Operation
MN/CDMQX.IOM
5–49
IMPORTANT
5.5.7
MONITOR: ODU
These read-only screens are operable only for CDM-QxL L-Band units.
Outdoor Unit Monitor:
BUC LNB (◄ ►,ENT)
Select BUC or LNB, using the ◄ ► arrow keys, then press
ENTER
.
5.5.7.1 MONITOR: ODU
Æ BUC
BUC: DC=47.8V,3.2A T=38oC
SW=1.1 PLL=Flt Pwr=02.1W
In this example, the BUC parameters displayed are as follows:
DC Pwr
(DC Power)
If a BUC supply is installed, displays measured BUC supply voltage and load
current, measured at the Tx-IF connector.
T
(Temperature)
If BUC FSK is enabled, displays BUC ambient temperature in
°C.
SW
If BUC FSK is enabled, displays the M&C software version of the BUC.
PLL
If BUC FSK is enabled, displays the fault status of the BUC PLL synthesizers.
Pwr
(Output)
If BUC FSK is enabled, displays the output power as measured by the BUC power
monitor.
Press
ENTER
or
CLEAR
to return to the previous menu.
5.5.7.2 MONITOR: ODU
Æ LNB
LNB Voltage: 13.1 volts
LNB Current: 235 mA (ENT)
In this example, the LNB parameters displayed are as follows:
LNB Voltage
LNB Voltage (in volts).
LNB Current
LNB Current, in mA.
Press
ENTER
or
CLEAR
to return to the previous menu.