Mocomtech CDM-QX User Manual
Page 253

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision
7
Appendix C
MN/CDMQX.IOM
C–35
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
BUC Output
Enable
BOE=
1 byte, value of
0,1
Command or Query.
Note: Valid when the BUC FSK comms and BUC power are
enabled.
Indicates BUC Output enable in the form x, where:
0=Off (Output Disabled)
1=On(Output Enabled)
Example: BOE=1 (BUC Output is Enabled)
BOE=
BOE?
BOE*
BOE#
BOE^
BOE? BOE=x
(see Description of
Arguments)
BUC Output
Power Level
N/A
4 bytes
Query only.
BUC output power level in the form xxx, where xxx is the value in
watts.
Returns 00.0 when FSK and BUC power are not enabled.
Example: BOL=08.3 (BUC reports output is 8.3 watts)
N/A BOL?
BOL=xx.x
(see Description of
Arguments)
BUC PLL
Alarm
N/A
1 byte, value of
0,1
Query only.
Note: Valid only when the FSK and BUC power are turned On.
Sets BUC PLL lock state in the form x, where:
0=Unlocked
1=Locked
Example: BPA=1 (BUC PLL is locked)
N/A BPA?
BPA=x
(see Description of
Arguments)
BUC Power
Control
BPC=
1 byte, value of
0,1
Command or Query.
Sets BUC power in the form x, where:
0=Disable BUC DC Power
1=Enable BUC DC Power
BPC=
BPC?
BPC*
BPC#
BPC^
BPC? BPC=x
(see Description of
Arguments)
BUC Software
Version
N/A
3 bytes
Query only.
Note: Valid only when the FSK and BUC power are turned On.
Indicates the BUC software version in the form x.x.
Example: BSV=1.1 (Software version 1.1)
N/A BSV?
BSV=x.x
(see Description of
Arguments)
BUC
Temperature
N/A
4 bytes
Query only.
Note: Valid only when the FSK and BUC power are turned On.
Indicates BUC temperature, in the form sxxx, where:
s=sign (+ or – character)
xx=value
If not available, response is –99
Example: BUT=-13 (BUC temperatures is -13
°C)
N/A BUT?
BUT=sxx
(see Description of
Arguments)