CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision
7
Appendix C
MN/CDMQX.IOM
C–13
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
RX Buffer
Size
RBS=
1 byte, value of
0 through 6
Command or Query.
RX Buffer size in the form x, where:
0=Buffer disabled
1=
± 512 bits
2=
± 1024 bits
3=
± 2048 bits
4=
± 4096 bits
5=
± 8192 bits
6=
± 16384 bits
Example: RBS=0
RBS=
RBS?
RBS*
RBS#
RBS$
RBS^
RBS@
RBS? RBS=x
(see description of
arguments)
RX Data
Clock Invert
RCI=
1 byte, value of
0, 1
Command or Query.
Invert Receive Data Clock in the form x, where:
0=Normal
1=Inverted
RCI=
RCI?
RCI*
RCI#
RCI$
RCI^
RCI@
RCI? RCI=x
(see Description of
Arguments)
RX Data
Invert
RDI=
1 byte, value of
0, 1
Command or Query.
Invert Receive Data in the form x, where:
0=Normal
1=Inverted
Example: RDI=1 (Inverted RX Data)
RDI=
RDI?
RDI*
RDI#
RDI$
RDI^
RDI@
RDI? RDI=x
(see Description of
Arguments)
RX
Descrambler
RDS=
1 byte, value of
0 1, 2
Command or Query.
RX Descrambler state in the form x, where:
0=Off
1=On (default descrambler type)
2=On (IESS-315 Turbo only)
RDS=
RDS?
RDS*
RDS#
RDS$
RDS^
RDS@
RDS? RDS=x
(see Description of
Arguments)
RX
Frequency
RFQ= 9
bytes
Command or Query.
Tx Frequency in the form xxxx.xxxx, where:
0950.0000 to 1950.0000 MHz (for L-Band units), 0050.0000 to
0090.0000 or 0100.0000 to 0180.0000 MHz ( for 70/140 MHz units)
Resolution = 100 Hz
Example: RFQ=0950.9872
RFQ=
RFQ?
RFQ*
RFQ#
RFQ$
RFQ^
RFQ@
RFQ? RFQ=xxxx.xxxx
(see Description of
Arguments)