3 data interfaces, 4 automatic uplink power control – Mocomtech CDM-QX User Manual
Page 42

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision
7
Introduction
MN/CDMQx.IOM
1–18
1.5.3
Data Interfaces
Note: Features not in the initial product release are identified in parentheses.
EIA-530
Synchronous RS-232
25-pin D-sub (female)
EIA-530
(3 selectable modes)
EIA-422/EIA-530 DCE (Rates up to 12 Mbps)
Also supports X.21(Rates up to 2.048 Mbps)
V.35 DCE (Rates up to 12 Mbps)
Synchronous RS-232 (Rates up to 300 kbps)
G.703 (Balanced)
1.544 Mbps T1 (Balanced 100
Ω)
2.048 Mbps E1 (Balanced 120
Ω)
15-pin D-sub (female)
G.703 (Unbalanced)
1.544 Mbps T1 (unbalanced 75
Ω)
2.048 Mbps E1 (unbalanced 75
Ω)
8.448 Mbps E2 (unbalanced 75
Ω)
BNC (female)
Multi-Port G.703 (Bal)
1 to 4 Ports E1 w/ D&I
2.048 Mbps E1 (balanced 120
Ω)
Note: All 4 ports must be synchronous
(4) RJ-45 Ports
EIA-612 / 613
(HSSI)
EIA-612/EIA-613 (Rates up to 20 Mbps)
50-pin, mini-D SCSI-II
HSSI (female)
Modem Alarms
(Present on all
modules)
Relay outputs (Tx, Rx & unit faults)
Demodulator I & Q test outputs (constellation)
Demodulator Rx Signal Level output (0 to 2.5 volts)
External carrier off input
15-pin D-sub (male)
Serial Remote Control
EIA-232 or EIA-485 modem control and monitoring
9-pin D-sub (male)
10/100BaseT
IP based monitoring & control
RJ-45
1.5.4
Automatic Uplink Power Control
Operating Mode
Requires Closed Network Framed mode for transport of Eb/No information from remote
modem (EDMAC can be enabled or disabled)
Target Eb/No range
0 to 9.9 dB at remote demod (default is 4.0 dB)
Max AUPC range
0 to 9 dB (default is 3 dB)
Monitor functions
Remote demod Eb/No
Tx power level increase
(front panel or via remote control interface)