Mocomtech CDM-QX User Manual
Page 73

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier®
Revision 7
Front Panel Operation
MN/CDMQX.IOM
5–7
Table 5-1. Prinicpal Menu Tree
Section
Title
Remarks
5.2 Opening
Screen
5.3 Main
Menu
Select: Config; Monitor; Test; Info; Save/Load; Utiity
5.4 Config
Select: Remote; Tx; Rx; Group; Frame; Interface; Ref; Mask; (CDM-QxL only) ODU
5.4.1
Config
→ Remote
Select: Local; Serial; Ethernet
5.4.2
Config
→ Tx
Select: FEC; Mod; Code; Data; Freq; On/Off; Pwr; Scram; Clk; Inv; Tx
α
5.4.3
Config
→ Rx
Select: FEC; Demod; Code; Data; Freq; Acq; Descram; Buf; Inv; Misc; CNC
5.4.4
Config
→ Group
Select: Modem; Redundancy
5.4.5
Config
→ Frame
Select: Unframed; EDMAC; EDMAC-2; D&I++
5.4.6
Config
→ Interface
Select: RS422; V.35; RS232; HSSI; G.703; QDI; None
5.4.7
Config
→ Ref
Select: Internal; 10MHz
5.4.8
Config
→ Mask
Select: Transmit; Receive; Reference; (CDM-QxL only) BUC; (CDM-QxL only) LNB
5.4.9
Config
→ ODU
(CDM-QxL only)
Select: BUC; LNB
5.5 Monitor
Select: Alarms; Rx-Params; Event-Log; Stats; AUPC; CNC; (CDM-QxL only) ODU
5.5.1
Monitor
→ Alarms
Select: Transmit; Receive; Unit; (CDM-QxL only) ODU
5.5.2
Monitor
→ Rx-Params Select: Eb/No, BER, ΔF, BUF, RSL
5.5.3
Monitor
→ Event-Log
Select: View; Clear-All
5.5.4
Monitor
→ Stats
Select: View; Clear-All; Config
5.5.5
Monitor
→ AUPC
(CDM-QxL only)
Framing is required for AUPC Monitor - Select: Remote Eb/No; Tx Power Increase
5.5.6
Monitor
→ CnC
Carrier in Carrier
® (CnC) indicates as Active or N ot Active
5.5.7
Monitor
→ ODU
(CDM-QxL only)
Select: ODU; LNB
5.6 Test
Select: Mode; BIST; Spec-Analyzer
5.6.1
Test
→ Mode
Select: Norm; IF Loop; Dig Loop; I/O Loop; RF Loop; Tx-CW; Tx-1,0
5.6.2 Test
Æ
BIST
Select: BERT-Config; BERT-Mon; BERT-Control
5.6.3 Test
Æ
Spec-Analyzer Select: Center-Freq; Span
5.7 Info
Select: Rem; Tx; Rx; Buffer; Frame; Interface; Mask; Ref; ID
5.8 Save/Load
Select: Save; Load
5.9 Utility
Select: RxBuffer; Clock; Ref; ID; Display; Firmware; FAST
5.9.1 Utility
Æ
RxBuffer
Select to Re-center buffer
5.9.2 Utility
Æ
Clock
Select to edit Real-Time Clock (Time and Date)
5.9.3 Utility
Æ
Ref
Select: Adjust; Warm-up Delay
5.9.4 Utility
Æ
ID
Select to edit Circuit ID
5.9.5 Utility
Æ
Display
Select to adjust VFD brightness
5.9.6 Utility
Æ
Firmware
Select: Update-CPLD; Information; Select
5.9.7 Utility
Æ
FAST
Select: Base; Slot1; Slot2; Slot3; Slot4
For the purpose of clarity, only the right-hand display area (or menu screen) is visually depicted
throughout the remainder of this chapter.